This problem hits Cisco bug ID CSCed03214.
The %SUPQ-4-CPUHB_RECV_STARVE: Still seeing receive queue stuck after throttling error message occurs when one of these Cisco Catalyst switches receives an invalid frame truncated to 1-byte. This can be due to collisions on a 10Mbps half-duplex connection or other error conditions on the line.
The interface and switch may pause indefinitely, and the switch is no longer able to send or receive STP Bridge Protocol Data Units (BPDUs) and other control protocol packets. This can cause a spanning tree loop and broadcast storm.
To locate the interface that receives 1-byte frames, issue the show platform port-asic receive command.
If an interface is configured for 10Mbps half-duplex, but shows non-zero and incrementing ifix counters, reconfigure the interface and connected device for 10Mbps full-duplex, or 100Mbps or 1000Mbps (any duplex).
If an interface is configured for 10Mbps full-duplex, 100Mbps or 1000Mbps (any duplex), but shows non-zero and incrementing ifix counters, the connected interface or wiring is likely the cause of the 1-byte frames. |